Client: MG Books
Value: £6.5k
MG Books Ltd in Devizes wanted a suspended ceiling installed into their back office and contacted Cre8tive Interiors. The office area got very cold in the winter and they felt that a suspended ceiling would do the trick. When we visited site, we could see that the space would also benefit from some LED Lighting. If the existing fittings were to be re-used it would detract from the look of the ceiling, and LED panels would also give a much better lighting levels in the space.
The levels had to be calculated based on the ceiling height and the area. In many offices, other suppliers have just replaced the existing fittings with LED in the same place and this has resulted in the area being too bright and not very pleasant to work in.
If computers are used, the LED panels also have to be office compliant with a UGR rating of less that 19. UGR stands for Unified Glare Rating. Most LED panels are mass produced and use poor quality LED’s which can give an inconsistent light level in the panel and this makes it unsuitable for offices. Fine for everything else, just not offices.
Existing Space and work in progress.
The first task is to measure everything and draw it. We always do this so we can accurately work out the material costs without guessing it. Once we have drawn the new grid and determined the new ceiling height the information is sent over to the electricians to carry out a lighting design.
You will notice one of the photographs below shows a fire detector and red cable. This was connected to the building system so had to be repositioned onto the new ceiling once finished.
Work in Progress
Final Photographs
Suspended Ceiling requirements?
We chose a very clean white ceiling pattern. It is possible to have a more textured design, or one that uses a tegular edge design but we do not like these. The tegular edge attracts dust and we think makes the ceiling look fussy. The tegular design is also more expensive than flat square edge. Also included in the price was 200mm bagged insulation that we fitted over the back of the suspended ceiling. We also blacked out the windows from the outside so people could not see the void above the suspended ceiling through the windows from the outside.
Electrically we provided emergency lighting as well, and also removed all of the existing fittings. Also supplied was an NICEIC certificate, certifying the work.
Any questions or requirements please give us a call on 01380 738844 or email us at [email protected]