Client: Webbs Motor Caravans
Value: 28k
Fire Rated Partitions
The difficulty with this project was that the client required offices above a mezzanine floor which means that the partitions below have to be fire rated, normally this means the glass has to be georgian wired. In this case we were able to use pyrocet clear glass to still give the 30 minute fire rating and yet not spoil the overall look of the offices.
The fire rated partitions system chosen was Komfort 75mm demountable partition system which allowed us to provide insulation inside the walls to give some degree of protection from the cold when the double doors to the showroom were opened to move caravans in and out. We could have used a cheap general 25mm thick partition roll which 99% of companies use as it is cheap, but in this case we used a Rockwool rw45 slab material designed to be better for insulation.
Partition Construction photos
Not shown are the suspended ceilings ceilings that we had to fit inside the offices. The one in the lower offices had to be 1 hour fire rated to give protection to the mezzanine floor. You can also see from the photographs the pink looking plasterboard on the metal columns of the mezzanine floor, this is fire protection board.
Fire rating and Building Regulations, not sure what to do?
Just give us a call or email. We understand partitioning and Building Regulations so can solve most problems. When it comes to offices it is crucial to protect people from any potential fire, the key is to make sure that the partitions give enough protection to allow people to escape. It is not acceptable to cut corners, so we always give the correct advice.