50mm wide Glazed Partitioning in Swindon

Client: Scots of Stow
Value: £3.9k

50mm wide Demountable Partitioning

50mm wide glazed office partitioning was the obvious solution to the customers requirements. The customer wanted some demountable partitioning to turn and unused office space into an open plan office space and a directors office. The system we recommended  was a 50mm wide glazed demountable system from Komfort that included a lot of glazed walls to allow light through and keep the area open and bright.

Privacy was a factor; the customer wanted each office and the meeting rooms to be private as possible. we used a wider 75mm system on the adjoining walls, and integral blinds in the glazed partitions so each office and meeting room could be enclosed when they needed. The walls were finished in a pale gray vinyl and the doors in a nice beech veneer to add some colour.

.

Existing open space

Drawing and planning work

Always important to measure what we have, by laying out where the partitions were needed, straight away we could see that the lights needed to be moved.

Construction and final photographs

Need any office partitioning?

Offices require demountable partitioning. As well as looking better than traditional stud and plasterboard there is a financial advantage as well. Please refer to our post Why use demountable partitioning?

Please give us a call on 01380 738844 or email us at [email protected]

Categories
All Project Categories Mezzanine Floors Office Refurbishments Partitioning Suspended Ceilings

Office Expansion in Corsham for Coombe Castle

Client: Coombe Castle
Value: £48k

Office Expansion in Corsham

This project consisted of converting a storage unit in to office space in order to provide some much needed office expansion. The project would involve fire protecting a mezzanine floor as this is required by Building Regulations if you have offices above, steel work and a suspended ceiling.  Ventilation had to be put round a chiller and fire sensors had to be installed within the chiller as it could not be moved to fit the fire protected board. Office windows had to be installed to match the rest of the building.

Upstairs needed a complete office fitting, so a suspended ceiling, dry lining the outer walls, decoration of the outer walls,  some fire rated partitioning to create a fire barrier between the offices and warehouse, as well as demountable partitioning within. Full electrical work including CAT2 lighting, 3 compartment perimeter trunking, flooring and new windows were also required. As always we follow our process, so the first step is to understand what the client wants, and then to assess what they have by taking photographs, and drawing everything.

Existing Space Photographs

It is a bit difficult to see from the photos, but essentially we had several areas to deal with. Underneath the mezzanine and on top of it was the main area, but included absolutely everything we do.

Building Regulations

It is crucial to consider Building Regulations when looking at layouts for offices. In particular fire ratings and Building Regulations which is a legal requirement. This particular project needed offices to be fitted on top of a mezzanine floor and so this is why it had to comply to the law.

If you need more information about Building Regulations, we have written a few things here.

Construction and finished photographs.

Office Expansion?

If you have a problem with your existing office space and need it altering as you are running out of space then Cre8tive can help. Please give us a call on 01380 738844.